Search Results
Who is my contact person or responsible salesperson?
Find your contact person on our webshop under "My Account" → "Company Account" → "Contacts." You can also contact us via email or phone for answers.
What promotions and offers do you have?
To see all our promotions and offers, check our webshop and weekly newsletters for updates on products, events, and more.
How do I become a customer at Aprilice?
To become a customer, you must represent a company and have an approved account on our webshop. Apply for an account at
https://b2b.aprilice.com/se_en/customer/account/create/
After approval, you can start shopping.
I can't find the answer to my question.
Feel free to contact us by emailing any of the following addresses or calling our hotline at +46 85 333 8668.
Order Questions → order@aprilice.se
Delivery Questions → leverans@aprilice.se
Financial Questions → ekonomi@aprilice.se
Complaint Questions → reklamation@aprilice.se
Phone hours:
Monday - Friday:
9:00 AM - 12:00 PM
1:00 PM - 4:00 PM
What do I do when error code 203 occurs?
All Growatt inverters sold by Aprilice perform an insulation resistance test between the panels and ground before starting. If the Growatt inverter detects any issues, error code 203 will be triggered. To troubleshoot this problem, a resistance measurement needs to be conducted to ensure that the strings do not have a resistance lower than 50KΩ.
If no issues are found in the strings, the installer can change register 125 to 0 in the inverter settings on the OSS platform. If this does not resolve the issue, please contact our Growatt support at growatt@aprilice.se for further support.
What do I do when error code 217 occurs?
Error code 217 indicates that something with the battery is not quite right. This usually does not imply a serious issue, but a visit to the site may be necessary.
For ARK Battery:
Measure the voltage in each battery and check the voltage. The voltage should be between 48-54V, with no more than a 0.5V difference between batteries.
If the voltage is between 32-47.9V, the batteries will need to be support-charged using a separate DC power supply capable of delivering 51V (DC) and 5-8A. Charge all batteries to 52V and start the system. After this, the problem should be resolved.
If the voltage is below 32V, the batteries need to be replaced. Please contact our Growatt Support at growatt@aprilice.se with pictures and information about the case for further help (including serial number, order number, and installer code).
For APX Battery:
If error code 217 appears on APX or if the APX battery is not visible on the OSS platform, please check the manual where description of issues for APX contains. If the manual does not resolve the problem, please check the MCS version and software of the battery & Power module (Version 15 & 18 are recommended).
If the version is lower than version 15 or different between the Control Module (98034-P2) & the battery (APX 5.0P-B1), various problems may occur. It is recommended to update all components via Growatt or on-site using an update file and a USB stick. Please contact our Growatt support at growatt@aprilice.se for instructions.
What do I do when error code 302 occurs?
Error code 302 indicates "No AC connection."
Check that there is AC-side voltage to the inverter and note down the values or take pictures. If error code 302 persists despite the presence of voltage, please contact our Growatt support at growatt@aprilice.se.
What do I do when error code 401 occurs?
Check that
- RS485A and RS485B are connected correctly.
- The address and baud rate for the smart meter should be as follows (instructions on how to do this are in the manual).
For CHNT (TPM-C):
Address: 004
Baud rate: 9600
For Eastron (TPM-CT-E & TPM-E):
Address: 002
Baud rate: 9600
Information on how RS485A and RS485B should be connected in the COM connector is available in the respective manuals for all inverters.
In very few cases, the RS485 cable may be damaged, so it is important to check that the cable is intact before troubleshooting is completed. This can usually be checked with measuring tools.
If a smart meter is not installed but the inverter shows error code 401, change registers 122,180,533 to 0 in the OSS platform under the inverter settings.